This is the basic procedure to data collection

1. Select a Data Collection File

 2.  Select "REC. coordinate file", and save the coordinate data converted from original data.

3. Select Coordinate Data File so that you can use Occupied Point coordinate data and Backsight coordinate data. (If coordinate data of known point is not necessary for use, pass this step)

4. Set Occupied Point, including Instrument Height, Point Number and Coordinate.

5. Set Backsight Point, Direction and Azimuth.

6. Start collecting and saving data.

 

$11  7.1   Selecting a file for data collection

Operation Steps

Key

Display

1) Press [MENU] to enter into MENU, and then press [1] (Collection).

[MENU]

[1]

  

-- Menu—          

 

1. Collection

2. Setout

 

3. Fileman

 

4. Program

 

5. Parameter

 

6. Calibration

-- Data Collect—          

 

1. Select File

2. Setup Station

 

3. Setup BSS

 

4. Sequence collection

 

5. Collection

 
 

 

2) Press [1] (Select File) and press [F4] (Enter) to select a work file.

[1]

[F4]

 

Choose file

 

>Work file

 

  Coor. File

 

  Code File

 

  Line file

 

Save

   

Enter

       

    

3) The screen shows Disk list. Choose the Disk which the work file is in

Select the desired file using [▲] or [▼] or create a new one *1

[▲] or [▼].

  F

SVY.COD                  

 

  I

B.MEA

  L

B.COO

 

  E

BAA.MEA

 
 

V.LSH

 
 

S.COD

New

Del

Read

Select

           
  1. 4)  Press ENT to confirm.

ENT

   

Choose file

 

>Work file

BAA.MEA

  Coor. File

 

  Code File

 

  Line file

 

Save

   

Enter

       
  1. 5)  Press [F1]and then the screen returns to DATA COLLECT MENU.

[F1]

-- Data Collect—          

 

1. Select File

2. Setup Station

 

3. Setup BSS

 

4. Sequence collection

 

5. Collection

 
 

 *1) Refer to “8.1.1 Create a new file” to create a new job

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

$11  7.2   Setup Station

The occupied point and direction angle in the data collect mode are linked with the occupied point and it is possible to set or change the occupied point and direction angle from the data collect mode.

Occupied point can be set by two setting methods as follow

1) Setting from the coordinate data stored in the internal memory

2) Direct key input

7.2.1          Setting the occupied point from data stored in the internal memory

Operation Steps

Key

Display

1) Press Menu and then press [1](Data Collection).

[MENU]

[1]

  

-- Data Collect—          

 

1. Select File

2. Setup Station

 

3. Setup BSS

 

4. Sequence collection

 

5. Collection

 
 

2) In Data Collection Menu, press [2] (Setup Station).

[2]

 

Setup Station

 

>STA

   

Code:

   

T.H.:

1.500

 
 


[*]file list

 

Input

Search

Info.

Read

       

 

3) Press [F4] (Read) to read the coordinates stored in the current coordinate file, if you hasn’t selected a coordinate job, it will prompt the file select list as shown on the right picture.

[F4]

 

  F

SVY.COD                  

 

  I

B.MEA

  L

B.COO

 

  E

BAA.MEA

 
 

V.LSH

 
 

S.COD

New

Del

Read

Select

           

  

4) Select the desired file using [▲] or [▼] and press [F4] (Select)

[▲] or [▼]

[F4]

 

  F

SVY.COD                  

 

  I

B.MEA

  L

B.COO

 

  E

BAA.MEA

 
 

V.LSH

 
 

S.COD

New

Del

Read

Select

           

 

5) You will see as shown on the right

 

  

PT.(B.COO) 1/2                                        

B001:0.000 0.000

PT1:100.000 100.00

ASD:1234.345 3456.234

 
       

Begin

End

Read

Select

 

 6) Select the desired point using [▲] or [▼] and press [F4] Select

[▲] or [▼]

[F4]

   

PT.(B.COO) 1/2                                        

B001:0.000 0.000

PT1:100.000 100.00

ASD:1234.345 3456.234

 
       

Begin

End

Read

Select

7) After selecting, press [ENT] to confirm and return to setup station  interface

[ENT]

Setup Station

 

STA

B001

 

>Code:

   

T.H.:

1.500

 
 

[*]file list

 

Input

 

Info.

Read

       

 

6) If you want to use Codes input the desired code

If you don’t want to use codes go to step 7)

Input code

Setup Station

 

STA

PT001

 

>Code:

SDG

 

T.H.:

1.500

 
     

Input

 

Info.

Read

       

7) Press ENT and you will see as the picture on the right.

Press ENT to save and finish.

Or press ESC to cancel

ENT

ENT

 

Save record?

ENT-Save

ESC-Not Save

Setup Station

 

STA

PT001

 

>Code:

SDG

 

T.H.:

1.500

 
     

Input

 

Info.

Read

       
 

 

7.2.2          Setting the occupied point by direct key input

Operation Steps

Key

Display

1) Press Menu and then press [1](Data Collection).

[MENU]

[1]

  

-- Data Collect—          

 

1. Select File

2. Setup Station

 

3. Setup BSS

 

4. Sequence collection

 

5. Collection

 
 

2) In Data Collection Menu, press [2] (Setup Station).

[2]

 

Setup Station

 

>STA

   

Code:

   

T.H.:

1.500

 
 


[*]file list

 

Input

Search

Info.

Read

       

 

3) Press [F1](Input) to enter coordinates of the occupied point

[F1]

Information

 

Pt.name:

   

STN:

     

STE:

 

m

 

STZ:

     

B.S.

Clear

Num.

Enter

             

 

 4) Input point name and coordinate N and press [F4] (Enter) to enter the next value.

Input the coordinate E and Z with the same method

Input name and coordinates

 

Information

 

Pt.name:

PT001

 

STN:

1000

   

STE:

10000

m

 

STZ:

10

   

B.S.

Clear

Num.

Enter

             

5) After inputting, press [ENT] to confirm and return to setup station  interface

[ENT]

Setup Station

 

STA

PT001

 

>Code:

   

T.H.:

1.500

 
 

[*]file list

 

Input

Search

Info.

Read

       

 

 

6) If you want to use Codes input the desired code

If you don’t want to use codes go to step 7)

Input code

Setup Station

 

STA

PT001

 

>Code:

SDG

 

T.H.:

1.500

 
     

Input

 

Info.

Read

       

7) Press ENT and you will see as the picture on the right.

Press ENT to save and finish.

Or press ESC to cancel

ENT

 

Save record?

ENT-Save

ESC-Not Save

Setup Station

 

STA

PT001

 

>Code:

SDG

 

T.H.:

1.500

 
     

Input

 

Info.

Read

       

Inputting Range:‐99999999.9999 ≤N, E, Z ≤ +99999999.9999 m

                                 ‐99999999.9999 ≤ N, E, Z ≤ +99999999.9999 ft

                                 ‐99999999.11.7 ≤ N, E, Z ≤ +99999999.11.7 ft + inch

$11  7.3   Setting the Azimuth (Backsight Point)

Setup station shall be done before setup BSS

The azimuth of backsight could be inverse calculated by the coordinates of instrument station and backsight station.

 

NOTE:

You can input the azimuth angle directly in angle measurement mode.

 

7.3.1          Setting the Backsight  point from data stored in the internal memory

Operation Steps

Key

Display

1) In Data Collection Menu, press [3] (Setup BSS).

[3]

 

Setup BSS

 

>BSS

   

Code:

   

T.H.:

1.500

 
 


[*]file list

 

Input

Search

Info.

Read

       

 

2) Press [F4] (Read) to read the coordinates stored in the current coordinate file, if you hasn’t selected a coordinate job, it will prompt the file select list. As shown on the right picture*

[F4]

 

  F

SVY.COD                  

 

  I

B.MEA

  L

B.COO

 

  E

BAA.MEA

 
 

V.LSH

 
 

S.COD

New

Del

Read

Select

           

  

3) Select the desired file using [▲] or [▼] and press [F4] Select

[▲] or [▼]

[F4]

 

  F

SVY.COD                  

 

  I

B.MEA

  L

B.COO

 

  E

BAA.MEA

 
 

V.LSH

 
 

S.COD

New

Del

Read

Select

           

 

4) You will see as shown on the right

 

  

PT.(B.COO) 1/2                                        

B001:0.000 0.000

PT1:100.000 100.00

ASD:1234.345 3456.234

 
       

Begin

End

Read

Select

5) Select the desired point using [▲] or [▼] and press [F4] (Select).

[▲] or [▼]

[F4]

PT.(B.COO) 1/2                                        

B001:0.000 0.000

PT1:100.000 100.00

ASD:1234.345 3456.234

BSS001:3454.242 1324.545

       

Begin

End

Read

Select

6) After selecting, press [ENT] to confirm and return to setup station interface.

[ENT]

Setup BSS

 

BSS

BSS001

 

>Code:

   

T.H.:

1.500

 
 

[*]file list

 

Input

 

Info.

Read

       

 

7) If you want to use Codes input the desired code.

If you don’t want to use codes go to step 8)

Input code

Setup BSS

 

BSS

BSS001

 

>Code:

SDG

 

T.H.:

1.500

 
     

Input

 

Info.

Read

       

8) Press ENT and you will see as the picture on the right.

Press ENT to save and finish.

Or press ESC to cancel.

ENT

 

Save record?

ENT-Save

ESC-Not Save

Setup Station

 

STA

PT001

 

>Code:

SDG

 

T.H.:

1.500

 
     

Input

 

Info.

Read

       

9) Then prompt if you need to setup azimuth using the BSS data or not. If you select [ENT] then the instrument will display the horizontal angle as Azimuth evermore.

Collimate BSS point and press [ENT].

Collimate BSS point

[ENT]

 

Aim at BS

ENT-SetHA

ESC-Quit

Setup BSS

 

STA

PT001

 

>Code:

SDG

 

T.H.:

1.500

 
     

Input

 

Info.

Read

       

  *Known point data is in the current coordinate file. If the coordinate data is in another coordinate file then you have to select the file as current coordinate file. In this time you can do it by pressing   (★).

 

 

 

7.3.2          Setting the Backsight point by direct key input

Operation Steps

Key

Display

1) In Data Collection Menu, press [3] (Setup BSS)

[3]

 

Setup BSS

 

>BSS

   

Code:

   

T.H.:

1.900

 
 


[*]file list

 

Input

Search

Info.

Read

       

 

2) Press [F1](Input) to enter coordinates of the occupied point

[F1]

Set BS

 

Pt.name:

   

BTN:

     

BTE:

 

m

 

BTZ:

     

B.S.

Clear

Num.

Enter

             

 

 3) Input point name and coordinate N and press [F4] (Enter) to enter the next value.

Input the coordinate E and Z with the same method

Input coordinates

 

Setup BSS

 

Pt.name:

PT001

 

BTN:

1000

   

BTE:

10000

m

 

BTZ:

10

   

B.S.

Clear

Num.

Enter

             

4) After inputting, press [ENT] to confirm and return to setup BSS  interface

[ENT]

Setup BSS

 

BSS

PT001

 

>Code:

   

T.H.:

1.500

 
 

[*]file list

 

Input

 

Info.

Read

       

 

5) If you want to use Codes input the desired code

If you don’t want to use codes go to step 6)

Input code

Setup BSS

 

STA

PT001

 

>Code:

SDG

 

T.H.:

1.500

 
     

Input

 

Info.

Read

       

 

6) Press ENT and you will see as the picture on the right.

Press ENT to save and finish.

Or press ESC to cancel

ENT

 

Save record?

ENT-Save

ESC-Not Save

Setup BSS

 

STA

PT001

 

>Code:

SDG

 

T.H.:

1.500

 
     

Input

 

Info.

Read

       

7) Then prompt if you need to setup azimuth using the BSS data or not. If you select [ENT] then the instrument will display the horizontal angle as Azimuth evermore.

Collimate BSS point and press [ENT]

Collimate BSS point

[ENT]

  

Aim at BS

ENT-SetHA

ESC-Quit

Setup BSS

 

STA

PT001

 

>Code:

SDG

 

T.H.:

1.500

 
     

Input

 

Info.

Read

       

 

$11  7.4   Sequence of Collection

You can set the sequence of data collection and edition.

There are two different ways to work.

In Data Collection Menu, press [4] (Sequence of collection)

-- Collection—             

 

1. Select file

2. Setup Station

 

>Meas first

  Edit First

3. Setup BSS

 

4. Sequence collection

 

5. Collection

 
 

                                                

EDIT→ MEAS: Set the PT# name, PCODE and target height firstly and then collect data.

MEAS→ EDIT: Collect data firstly, and then allow the customer to edit the collected PT# name, PCODE, target height

 

 

 

$11  7.5   Measuring and saving the data

Operation Steps

Key

Display

1) In Data Collection Menu, press [3] (Setup BSS).

[3]

  

Vz:

104°34’20”

 

HR:

90°09’12”

 

N:

Sing

m

E:

   

Z:

   

Save

Meas

Mode

P1/2

       

   

2) Collimate target

Collimate the prism

    

Vz:

104°34’20”

 

HR:

90°09’12”

 

N:

Sing

m

E:

   

Z:

   

Save

Meas

Mode

P1/2

       

4) Start measurement by pressing [F2] (Meas).

[F2]

Vh:

104°34’20”

 

HR:

90°09’12”

 

N:

2411.552

ft

E:

345.234

 

Z:

23.231

 

Save

Meas

Mode

P1/2

       

5) Press [F1] (Save) to start coordinates measurement and record the result.

[F1]

Vh:

104°34’20”

 

HR:

90°09’12”

 

N:

 

ft

E:

345.234

 

Z:

23.231

 

Save

Meas

Mode

P1/2

       

   

6) You will see as shown on the right window

If you want to change the name, press [F2](Clear) and input the point name

[F2]

Input Point name

 

 

                                  

 

Information

 

Pt.name:

N001

 

Code:

PT

   

  T.H.:

2.100

m

 

 [*]Save WORK&COOR. file

B.S.

Clear

Alph.

Enter

               

 

7)Press [ENTER]to confirm and Save point

[ENTER]

Vh:

104°34’20”

 

Saved

 

HR:

90°09’12”

 

N:

 

ft

E:

345.234

 

Z:

23.231

 

Save

Meas

Mode

P1/2

       

 